Description
SF4 Unvented Pressure Reducing Kit Inc Expansion Vessel + Check Valve
The SF4 kit contains a 2 litre expansion vessel and check
valve to prevent expanded hot water re-entering the cold water supply. It also
comes with a pressure reducing valve, for areas where water pressure is high.
The SF4 kit is suitable for use with small unvented water heaters such as the
Hyco Speedflow unit and Ariston Europrisma.
• 2 Litre Stainless Steel Expansion Vessel
• 15mm Single Check Valve
• 1/2" F/F Pressure reducing valve
In smaller unvented systems it may be possible to
accommodate the expansion of water which occurs during the heating cycle in the
system pipe work, thus reducing the need to fit many of the water controls.
However, the expanded hot water must not enter any supply pipe to which a cold
water draw off is connected. For this to be achieved the pipe work between the
last cold water draw off and the water heater must be of sufficient volume to
accommodate the expansion.
(Kit SF4) If the pipework length does not reach these minimum distances, an
expansion vessel and non return valve is required.
|
Length of
pipe
|
Capacity
10Ltr
|
Capacity
15Ltr
|
Capacity
30Ltr
|
|
15mm Pipe
|
2.8m
|
4.2m
|
Required
|
|
22mm Pipe
|
1.5m
|
2.2m
|
Required
|